'Script to check the status of a DOMAIN controller and report to Nagios
'requires DCDIAG.EXE
'Author: Felipe Ferreira
'Version: 3.0
'
'Mauled over by John Jore, j-o-h-n-a-t-j-o-r-e-d-o-t-n-o 16/11/2010 to work on W2K8, x32
'as well as remove some, eh... un-needed lines of code, general optimization as well as adding command parameter support
'This is where i found the original script, http://felipeferreira.net/?p=315&cpage=1#comments
'Tested by JJ on W2K8 SP2, x86
' W2K3 R2 SP2, x64
'Version 3.0-JJ-V0.2
'Todo: Proper error handling
' Add /help parameter
' Add support for the two tests which require additional input (dcpromo is one such test)
'Version 3.0-JJ-V0.3
' Removed some surplus language detection code
' Including non-working English test on a W2K8 x32 DC
' Added support for multi-partition checks like 'crossrefvalidation'. Previously the last status result would mask previous failures
' Incorporated Jonathan Vogt's german and multiline tests
'Force all variables to be declared before usage
option explicit
'Array for name and status (Ugly, but redim only works on last dimension, and can't set initial size if redim
dim name(), status()
redim preserve name(0)
redim preserve status(0)
redim preserve lock(0)
'Debug switch
dim verbose : verbose = 0
'Return variables for NAGIOS
const intOK = 0
const intWarning = 1 'Not used. What dcdiag test would be warning instead of critical?
const intCritical = 2
const intUnknown = 3
'Lang dependend. Default is english
dim strOK : strOK = "passed"
dim strNotOK : strNotOk = "failed"
'Call dcdiag and grab relevant output
exec(cmd)
'Generate NAGIOS compatible output from dcdiag
printout()
'call dcdiag and parse the output
sub exec(strCmd)
'Declare variables
dim objShell : Set objShell = WScript.CreateObject("WScript.Shell")
dim objExecObject, lineout, tmpline
lineout = ""
'Command line options we're using
pt strCmd
Set objExecObject = objShell.Exec(strCmd)
'Loop until end of output from dcdiag
do While not objExecObject.StdOut.AtEndOfStream
tmpline = lcase(objExecObject.StdOut.ReadLine())
'Check the version of DCDiag being used and change the global 'passed' / 'failed' strings
call DetectLang(tmpline)
if (instr(tmpline, ".....")) then
'testresults start with a couple of dots, reset the lineout buffer
lineout= tmpline
'pt "lineout buffer '" & lineout & "'"
else
'Else append the next line to the buffer to capture multiline responses
lineout = lineout + tmpline
'pt "lineout buffer appended '" & lineout & "'"
end if
if instr(lineout, lcase(strOK)) then
'we have a strOK String which means we have reached the end of a result output (maybe on newline)
call parse(lineout)
lineout = ""
end if
loop
'Why call this at the end? Is it not pointless as we've looped through the entire output from dcdiag in the above loop?!?
'call parse(lineout)
end sub
sub DetectLang(txtp)
'Change from looking for English words if we find the string below:
if (instr(lcase(txtp), lcase("Verzeichnisserverdiagnose"))) then 'German
pt "Detected German Language, changing the global test strings to look for"
strOK = "bestanden"
strNotOk = "nicht bestanden"
end if
end sub
sub parse(txtp)
'Parse output of dcdiag command and change state of checks
dim loop1
'Is this really required? Or is it for pretty debug output only?
txtp = Replace(txtp,chr(10),"") ' Newline
txtp = Replace(txtp,chr(13),"") ' CR
txtp = Replace(txtp,chr(9),"") ' Tab
do while instr(txtp, " ")
txtp = Replace(txtp," "," ") ' Some tidy up
loop
' We have to test twice because some localized (e.g. German) outputs simply use 'not', or 'nicht' as a prefix instead of 'passed' / 'failed'
if instr(lcase(txtp), lcase(strOK)) then
'What are we testing for now?
pt "Checking :" & txtp & "' as it contains '" & strOK & "'"
'What services are ok? 'By using instr we don't need to strip down text, remove vbCr, VbLf, or get the hostname
for loop1 = 0 to Ubound(name)-1
if (instr(lcase(txtp), lcase(name(loop1)))) AND (lock(loop1) = FALSE) then
status(loop1)="OK"
pt "Set the status for test '" & name(loop1) & "' to '" & status(loop1) & "'"
end if
next
end if
' if we find the strNotOK string then reset to CRITICAL
if instr(lcase(txtp), lcase(strNotOK)) then
'What are we testing for now?
pt txtp
for loop1 = 0 to Ubound(name)-1
if (instr(lcase(txtp), lcase(name(loop1)))) then
status(loop1)="CRITICAL"
'Lock the variable so it can't be reset back to success. Required for multi-partition tests like 'crossrefvalidation'
lock(loop1)=TRUE
pt "Reset the status for test '" & name(loop1) & "' to '" & status(loop1) & "' with a lock '" & lock(loop1) & "'"
end if
next
end if
end sub
'outputs result for NAGIOS
sub printout()
dim loop1, msg : msg = ""
for loop1 = 0 to ubound(name)-1
msg = msg & name(loop1) & ": " & status(loop1) & ". "
next
'What state are we in? Show and then quit with NAGIOS compatible exit code
if instr(msg,"CRITICAL") then
wscript.echo "CRITICAL - " & msg
wscript.quit(intCritical)
else
wscript.echo "OK - " & msg
wscript.quit(intOK)
end if
end sub
'Print messages to screen for debug purposes
sub pt(msgTxt)
if verbose then
wscript.echo msgTXT
end if
end sub
'What tests do we run?
function cmd()
dim loop1, test, tests
const intDefaultTests = 6
cmd = "dcdiag " 'Start with this
'If no command line parameters, then go with these defaults
if Wscript.Arguments.Count = 0 Then
redim preserve name(intDefaultTests)
redim preserve status(intDefaultTests)
redim preserve lock(intDefaultTests)
'Test name
name(0) = "services"
name(1) = "replications"
name(2) = "advertising"
name(3) = "fsmocheck"
name(4) = "ridmanager"
name(5) = "machineaccount"
'Set default status for each named test
for loop1 = 0 to (ubound(name)-1)
status(loop1) = "CRITICAL"
lock(loop1) = FALSE
cmd = cmd & "/test:" & name(loop1) & " "
next
else
'User specified which tests to perform.
for loop1 = 0 to wscript.arguments.count - 1
if (instr(lcase(wscript.Arguments(loop1)), lcase("/test"))) then
'If parameter is wrong, give some hints
if len(wscript.arguments(loop1)) < 6 then
wscript.echo "Unknown parameter. Provide name of tests to perform like this:"
wscript.echo vbTAB & "'cscript //nologo " & Wscript.ScriptName & " /test:advertising,dfsevent'"
wscript.quit(intUnknown)
end if
'Strip down the test to individual items
tests = right(wscript.arguments(loop1), len(wscript.arguments(loop1))-6)
pt "Tests: '" & tests & "'"
tests = split(tests,",")
for each test in tests
cmd = cmd & " /test:" & test
'Expand the array to make room for one more test
redim preserve name(ubound(name)+1)
redim preserve status(ubound(status)+1)
redim preserve lock(ubound(lock)+1)
'Store name of test and status
name(Ubound(name)-1) = test
status(Ubound(status)-1) = "CRITICAL" 'Default status. Change to OK if test is ok
lock(Ubound(lock)-1) = FALSE 'Don't lock the variable yet.
'pt "Contents: " & name(Ubound(name)-1) & " " & status(Ubound(status)-1)
next
end if
next
end if
'We end up with this to test:
pt "Command to run: " & cmd
end function